We have collected the most relevant information on Diagnostic Audiometer Specifications. Open the URLs, which are collected below, and you will find all the info you are interested in.
						
						
						
						
						
						r27a Diagnostic Audiometer | Eartech Resonance
						https://www.eartech-resonance.com/products/r27a/#:~:text=%20Audiometry%20Specification%20%201%20125%20%E2%80%93%208000,250%20%E2%80%93%208000%20Hz%20%28with%20B71-W%29%20More%20
 
						
						
						
						Diagnostic Audiometer - inventis
						https://www.inventis.it/sites/default/files/products/tech-files/technical-sheet-HARP.pdf
Diagnostic Audiometer TECHNICAL SPECIFICATIONS Description Harp is an advanced diagnostic audiometer, capable of performing fast and accurate air, bone and speech audiometric exams, as well as several additional tests including a two-channel master hearing aid. Classification Type 2 pure tone audiometer (EN 60645-1) Type A or A-E speech audiometer …
 
						
						
						
						Diagnostic Audiometer - For Hearing Care Professionals
						https://starkeypro.com/pdfs/equipment/Diagnostic_Audiometer_Harp.pdf
Standards .....Audiometer: EN 60645 -1 / ANSI S3.6, Type 2 Speech: EN60645-2 / ANSI S3.6 type A-E Safety: EN 60601-1, Class 2, Type BF EMC: EN 60601-1-2 Classification .....Class IIa (MDD …
 
						
						
						
						Diagnostic Audiometer
						https://www.inventis.it/sites/default/files/products/tech-files/technical-sheet-BELL.pdf
Diagnostic Audiometer TECHNICAL SPECIFICATIONS Description Bell is a basic diagnostic audiometer, capable of performing fast and accurate air and bone conduction threshold examinations. Classification Basic: Type 4 pure tone audiometer (EN 60645-1) Plus: Type 3 pure tone audiometer (EN 60645-1) Available signals
 
						
						
						
						r27a Diagnostic Audiometer – Resonance
						http://www.resonance-audiology.com/en/r27a-diagnostic-audiometer/
RANGE • Frequency range: 125 – 8000 Hz (with DD45) 125 – 12500 Hz (with HDA280) 250 – 8000 Hz (with B71W) • Range stimuli level -10 up to 120 dB HL ACCURACY • Frequency < 0.5% • Distortion < 1% • Attenuator linearity 1dB per 5 dB step, max 3 dB whole range TYPE OF SIGNALS • Pure tone: sine wave 125 ...
 
						
						
						
						Technical Specifications AD629 Diagnostic Audiometer
						https://www.e3diagnostics.com/-/media/e3-diagnostics/shared/pdf/data-sheets/interacoustics/technical_specification_ac40/technical_specification_ad629.pdf?la=en&hash=3C0465D86695767D39363AC555E4ACED44513CD7
Diagnostic Suite - Noah, OtoAccess and XML compatible Dimensions (LxWxH) 36.5 x 29.5 x 6.5 cm / 14.4 x 11.6 x 2.6 inches Weight 3.3kg/6.3lb Power supply 100-240 V~, 50-60Hz max 0.5A Operation environment Temperature: 15-35°C Re. Humidity: 30-90% Non condensing Transport and storage Transport temperature: -20-50°C
 
						
						
						
						Technical Specifications AD629 Diagnostic Audiometer
						http://www.rdr.com.mx/wp-content/uploads/2018/12/ESP.TEC_.-AD629.pdf
Input Specifications TB 100uVrms at max. gain for 0dB reading Input impedance : 3.2KOhm Mic.2 100uVrms at max. gain for 0dB reading Input impedance : 3.2KOhm CD 7mVrms at max. gain for 0dB reading Input impedance : 47KOhm TF (side panel) 100uVrms at max. gain for 0dB reading Input impedance : 3.2KOhm
 
						
						
						
						Audiometer - MedRx AVANT A2D+ PC-based Diagnostic Audiometer
						https://www.medrx-diagnostics.com/products/audiometers/avant-a2d
The product is compact, Approx. 16 cm x 12 cm x 3 cm (L x W x H), and when combined with a laptop is portable and easily configured for any office layout. Features: Dual Channel Diagnostic Audiometer. Complete Air, Bone, Speech and Masking Audiometry. Built-in Special Tests, Word Lists and Auto-Scoring.
 
						
						
							
						Now you know Diagnostic Audiometer Specifications
						Now that you know Diagnostic Audiometer Specifications, we suggest that you familiarize yourself with information on similar questions.